Thermocromex Installation Details - Table of Contents

 

 

Description

DetailsAdobe(PDF)

DetailsAutoCad(DWG)

DetailsBIM(RVT)

Details3D (PDF)

 

 THERMOCROMEX OVER CMU, POURED IN PLACE AND TILT WALL
Masonry Substrate 1.01 1.01a 1.01 RVT 1.01-3D
Smooth Concrete Substrate (Poured in Place Concrete or Tilt Wall) 1.02 1.02a 1.02 RVT 1.02-3D 
CMU Wall - Casing Bead at Concrete Foundation 1.03 1.03a 1.03 RVT 1.03-3D
CMU Wall - Foundation Screed at Concrete Foundation 1.04 1.04a 1.04 RVT 1.04-3D
PIP/Tilt Wall - Casing Bead at Concrete Foundation 1.05 1.05a 1.05 RVT 1.05-3D
PIP/Tilt Wall - Foundation Screed at Concrete Foundation 1.06 1.06a 1.06 RVT 1.06-3D
Two Dissimilar Substrates 1.07 1.07a 1.07 RVT 1.07-3D
Construction Joint in Tilt Wall 1.08 1.08a 1.08 RVT 1.08-3D
Construction Joint in Tilt Wall with Two Piece Expansion Joint 1.09 1.09a 1.09 RVT 1.09-3D
Two Piece Expansion Joint at Control Joint in CMU Wall 1.10 1.10a 1.10 RVT 1.10-3D
Control Joint with Casing Bead on CMU Wall 1.11 1.11a 1.11 RVT 1.11-3D
    
THERMOCROMEX OVER CMU - ECONOMY CONFIGURATION This option is only less expensive in areas with low labor rates as it uses less expensive materials but requires two labor passes
CMU Economy - Masonry Substrate with Base Coat1E.011E.01a1E.01RVT1E.01-3D
CMU Economy - Casing Bead at Concrete Foundation1E.021E.02a1E.02RVT1E.02-3D
U Economy - Foundation Screed at Concrete Foundation1E.031E.03a1E.03RVT1E.03-3D
Two Dissimilar Substrates1E.041E.04a1E.04RVT1E.04-3D
Expansion Joint with Casing Bead in CMU Economy1E.051E.05a1E.05RVT1E-05-3D
Two Piece Expansion Joint at Control Joint in CMU Economy1E.061E.06a1E.06RVT1E-06-3D
Control Joint on CMU Economuy1E.071E.07a1E.07RVT1E-07-3D
  
 THERMOCROMEX OVER FRAME AND SHEATHING
 Sheathed Framing Substrate 2.01 2.01a 2.01 RVT 2.01-3D
 Horizontal or Vertical Expansion Joint 2.02 2.02a 2.02 RVT 2.02-3D
 Horizontal Expansion Joint 2.03 2.03a 2.03 RVT 2.03-3D
 Expansion Joint Intersection 2.04 2.04a 2.04 RVT 2.04-3D
 Expansion Joint at Casing Bead or Foundation Screed 2.05 2.05a 2.05 RVT  2.05-3D
 Horizontal Flashing and Expansion Joint 2.06 2.06a 2.06 RVT 2.06-3D
 Termination at Concrete Foundation 2.07 2.07a 2.07 RVT 2.07-3D
 Termination at Storefront Window - Head & Sill 2.08 2.08a 2.08 RVT 2.08-3D
 Termination at Storefront Window - Jamb 2.09 2.09a 2.09 RVT 2.09-3D
 Termination at Flashing Nail on Window 2.10 2.10a 2.10 RVT 2.10-3D
 Storefront Window - Set back 2.11 2.11a 2.11 RVT 2.11-3D
 Termination at Wood Window 2.12 2.12a 2.12 RVT 2.12-3D
 Inside Corner 2.13 2.13a 2.13 RVT 2.13-3D
 Inside Corner Control Joint 2.14 2.14a 2.14 RVT 2.14-3D
 Outside Corner 2.15 2.15a 2.15 RVT 2.15-3D
 Termination at Roof 2.16 2.16a 2.16 RVT 2.16-3D
 Termination at Roof/Wall 2.17 2.17a 2.17 RVT 2.17-3D
 Termination at Sloped Roof 2.18 2.18a 2.18 RVT 2.18-3D
 Termination at Parapet/Wall Intersection 2.19 2.19a 2.19 RVT 2.19-3D
 Soffit with Continuous Vent 2.20 2.20a 2.20 RVT 2.20-3D
 Soffit/Fascia Intersection 2.21 2.21a 2.21 RVT 2.21-3D
 Termination at Deck Flashing 2.22 2.22a 2.22 RVT 2.22-3D
 Sloped Sill 2.23 2.23aN/AN/A
 Termination at EIFS/Lap Siding 2.24 2.24a 2.24 RVT 2.24-3D
 Hose Bib Penetration 2.25 2.25a 2.25 RVT 2.25-3D
 Pipe Railing Attachment 2.26 2.26a 2.26 RVT 2.26-3D
 Parapet Flashing 2.27 2.27a 2.27 RVT 2.27-3D
 Two Dissimilar Substrates 2.28 2.28a 2.28 RVT 2.28-3D
 Termination at Hollow Metal Door Frame 2.29 2.29a 2.29 RVT 2.29-3D
 Termination at Inset Door Frame 2.30 2.30a 2.30 RVT 2.30-3D
 
THERMOCROMEX OVER FRAME AND SHEATHING WITH INSULATION BOARD
 Sheathed Framing Substrate with Insulation Board 2.01 IB 2.01a IB2.01 RVT IB2.01-3D
 Horizontal or Vertical Expansion Joint with Insulation Board 2.02 IB 2.02a IB2.02 RVT IB2.02-3D
 Horizontal Expansion Joint with Insulation Board 2.03 IB 2.03a IB 2.03 RVT IB2.03-3D
 Expansion Joint Intersection with Insulation Board 2.04 IB 2.04a IB 2.04 RVT IB2.04-3D
 Expansion Joint at Casing Bead or Foundation Screed with Insulation Board 2.05 IB 2.05a IB 2.05 RVT IB2.05-3D
 Horizontal Flashing and Expansion Joint with Insulation Board 2.06 IB 2.06a IB 2.05 RVT IB2.05-3D
 Termination at Concrete Foundation with Insulation Board 2.07 IB 2.07a IB 2.07 RVT IB2.07-3D
 Termination at Storefront Window - Head & Sill with Insulation Board 2.08 IB 2.08a IB 2.08 RVT IB2.08-3D
 Termination at Storefront Window - Jamb with Insulation Board 2.09 IB 2.09a IB 2.09 RVT IB2.09-3D
 Termination at Flashing Nail on Window with Insulation Board 2.10 IB 2.10a IB 2.10 RVT IB2.10-3D
 Storefront Window - Set back with Insulation Board 2.11 IB 2.11a IB 2.11 RVT IB2.11-3D
 Termination at Wood Window with Insulation Board 2.12 IB 2.12a IB 2.12 RVT IB2.12-3D
 Inside Corner with Insulation Board 2.13 IB 2.13a IB 2.13 RVT IB2.13-3D
 Inside Corner Control Joint with Insulation Board 2.14 IB 2.14a IB 2.14 RVT IB2.14-3D
 Outside Corner with Insulation Board 2.15 IB 2.15a IB 2.15 RVT IB2.15-3D
 Termination at Roof with Insulation Board 2.16 IB 2.16a IB 2.16 RVT IB2.16-3D
 Termination at Roof/Wall with Insulation Board 2.17 IB 2.17a IB 2.17 RVT IB2.17-3D
 Termination at Sloped Roof with Insulation Board 2.18 IB 2.18a IB 2.18 RVT IB2.18-3D
 Termination at Parapet/Wall Intersection with Insulation Board 2.19 IB 2.19a IB 2.19 RVT IB2.19-3D
 Soffit with Continuous Vent with Insulation Board 2.20 IB 2.20a IB 2.20 RVT IB2.20-3D
 Soffit/Fascia Intersection with Insulation Board 2.21 IB 2.21a IB 2.21 RVT IB2.21-3D
 Termination at Deck Flashing with Insulation Board 2.22 IB 2.22a IB 2.22 RVT IB2.22-3D
 Sloped Sill with Insulation Board 2.23 IB 2.23a IBN/A2.23-3D 
 Termination at EIFS/Lap Siding with Insulation Board 2.24 IB 2.24a IB 2.24 RVT IB2.24-3D
 Hose Bib Penetration with Insulation Board 2.25 IB 2.25a IB 2.25 RVT IB2.25-3D
 Pipe Railing Attachment with Insulation Board 2.26 IB 2.26a IB 2.26 RVT IB2.26-3D
 Parapet Flashing with Insulation Board 2.27 IB 2.27a IB 2.27 RVT IB2.27-3D
 Two Dissimilar Substrates with Insulation Board 2.28 IB 2.28a IB 2.28 RVT IB2.28-3D
 Termination at Hollow Metal Door Frame with Insulation Board 2.29 IB 2.29a IB 2.29 RVT IB2.29-3D
 Termination at Inset Door Frame with Insulation Board 2.30 IB 2.30a IB 2.30 RVT IB2.30-3D
 
THERMOCROMEX OVER FRAME AND SHEATHING WITH INSULATION BOARD & Z FURRING MEMBERS
Sheathed Framing Substrate with Insulation Board & Z Furring Members2.01 Z2.01a Z2.01 RVT Z 22.01Z - 3D
 
 THERMOCROMEX INTERIOR APPLICATION
 Interior Framing with Cement Board Sheathing 2.31 2.31a 2.31 RVT 2.31-3D
 
 THERMOCROMEX - CEMENT BOARD
 Cement Board - Soffits Only 2.322.32a2.32 RVT2.32 - 3D
 THERMOCROMEX OVER EPS TRM
 EPS Trim 4.01 4.01a 4.01 RVT 4.01-3D
 THERMOCROMEX OVER AAC LIGHT WEIGHT CONCRETE
 Exterior Wall 5.01 5.01a 5.01 RVT 5.01-3D
 Exterior Wall Reinf. Loc. (Panel) 5.02 5.02a 5.02 RVT 5.02-3D
 Exterior Wall Reinf. Loc. (Block) 5.03 5.03a 5.03 RVT 5.03-3D
 Floor Panel Span Transition (Panel) 5.04 5.04a 5.04 RVT 5.04-3D
 Floor Panel Span Transition (Block) 5.05 5.05a 5.05 RVT 5.05-3D
 Floor/Roof Panels End Brg. (Panel) 5.06 5.06a 5.06 RVT 5.06-3D
 Floor/Roof Panels End. Brg. (Block) 5.07 5.07a 5.07 RVT 5.07-3D
 Electrical Service 5.08 5.08a  5.08 RVT 5.08-3D
 Typical Reinforced Wall Panel 5.09 5.09a 5.09 RVT 5.09-3D

 

NOTE: All components designated in drawings shall be designed, detailed and engineered by representatives of the Architect, owner or contractor in compliance with model codes, architectural and engineering requirements pertaining to specific building projects. Southwest Progressive Enterprises Inc., makes no representation regarding conformity of its suggestions to model building codes, engineering criteria, specific applications or project locations. Southwest Progressive Enterprises Inc., makes no warranty, expressed or implied as to the architectural design, engineering, or workmanship of projects using Thermocromex.